Patient-anatomy-referenced multiscale modelling of median nerve conduction in carpal tunnel syndrome

nature.com 04.11.2026 01:00 7 views

Carpal Tunnel Syndrome (CTS) is a common compressive peripheral neuropathy causing focal conduction slowing and sensory dysfunction. Existing computational models are either mechanical or electrophysiological in isolation, precluding mechanistic understanding of nerve dysfunction across severity grades. We introduce a multiscale computational system built on a patient-anatomy-referenced median nerve pathway, rigidly registered and anatomically deformed against this patient’s own segmented bone and skin geometry, with the compression zone defined at 0–29.4 mm from the detected wrist point.

A reduced-order conduction-velocity model, a FitzHugh–Nagumo (FHN) reaction–diffusion model and an unfitted McIntyre–Richardson–Grill (MRG) double-cable model were analysed on this pathway. The velocity and FHN models were calibrated to Kimura’s Normal and Mild data (zone velocities 57–59 and about 41 m/s) and predicted about 24 and 7 m/s for Moderate and Severe CTS. The MRG model predicted a normal velocity of 56.1 m/s without fitting and complete conduction block in Severe CTS, but under-predicted Mild and Moderate slowing (52.8 and 43.6 m/s).

Convergence, sensitivity analysis and ten-run registration repeatability are reported, with registration limitations (16.0% of tube-surface points outside the skin) disclosed rather than assumed away. The framework is a research platform for peripheral neuropathy investigation, not a validated diagnostic tool. The authors acknowledge Institute of Biomedical Engineering & Technology, Liaquat University of Medical and Health Sciences and Salim Habib University for providing the academic environment and resources necessary to conduct this study.

The authors acknowledge the use of AI-assisted tools during manuscript preparation for language refinement, code debugging support, and editorial consistency checking. The authors reviewed, verified, and take full responsibility for all scientific content, analyses, interpretations, and conclusions presented in this manuscript. The authors declare that no specific funding was received for this research.

Institute of Biomedical Engineering & Technology, Liaquat University of Medical & Health Sciences, Jamshoro, Pakistan Gul Munir, Muhammad Fahad Shamim & Sarmad Shams Department of Biomedical Engineering, Salim Habib University, Karachi, Pakistan Biomedical Engineering Department, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Kingdom of Saudi Arabia The authors declare no competing interests. This study utilised publicly available medical imaging datasets and anatomical atlas data. No patient-specific data requiring ethical approval were collected.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. Below is the link to the electronic supplementary material. Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material.